Open the normal LED light 24V auxiliary power normal DC 300V normal welding, the minimum current of the minimum current is not the two LED lights on the board.
The replacement is 3140 without fruit. The voltage on both sides of the potentiometer is normal about seven or eight V. After measuring the resistance of the potentiometer, the intermediate foot to the small vertical plate increases, resulting in the signal transmission is not up.
No load or normal current is measured. The main electrical more than 500 V is normal, and the normal load is eighty V. The size of the digital display is normal. The Z24 has more than 20 V output to the earth voltage, and normal 14V should be normal. The test current of a group of one group is also not coming up. The adjustable resistance of the current potentiometer to the small plate is too large to be replaced by a small normal solution.
故障:風(fēng)機聲音大,電流不穩(wěn)定
Fault: the fan is loud and the current is unstable
After starting the fan, the voice is very large, and the welding current is unstable. After checking, it is found that a fan blade is missing. After replacing the fresh air blower, the sound is normal, the fast connector has been damaged, and the welding current is stable after replacement. Many manufacturers directly fix the shunt to fast plug. It is very easy to cause the shunt heating, damage the shunt and burn out the detection line on the top of the distributor. This is something we need to pay attention to. This will cause the maximum current uncontrolled after the burn out.